© 2004-2005 Goodman Manufacturing Company, L.P. INSTALLATION INSTRUCTIONS GMS9/GCS9 HIGH ALTITUDE GAS ORIFICE CHART Natural Propane NOTE: In Canada, gas furnaces are certified to 4500 feet. 0-7000 A condensing gas furnace achieves its high level of efficiency by

Product Description of [post_title] below:


Domestic Shipping: This item is also available for shipping to select countries outside the U.S.
International Shipping: This item is not eligible for international shipping.
Average Customer Review: 9/10

Natural Gas Drill Size: #56 (.0465") Main Burner Gas Appliance Orifices – Brass (Fairview) Thread Size Part Number 1/8 MPT 661043 1/8 MPT 661044 1/8 MPT 661045 1/8 MPT 661054 Orifice Capacities Natural Gas – 1050 BTU – 0.65 SP – GR

natural gas in your area. NOTE: If furnace is being installed at an altitude of more than 2000 feet above sea level, you must derate the furnace. Natural Gas Orifice Size. ELEVATION GAS Up 2001 3001 4001 5001 6001* 7001* 8001* 9001*

Comfortmaker Comfortmaker Gas 95 All models beginning with C9UHX Gibson Condensing Furnace 92 All KG6RL models Goodman Gas $aver Gasd (Nat/LP) 95 All models beginning with AMS95 furnace Natural or Propane gas

Bryant Gas Furnace Error Code 33 Your furnace then shoots natural gas close to the ignitor, igniting the gas which LH33Zs004, which will work on most Bryant, Currier, Goodman · Heil · Lennox air furnace equipped for use with natural gas

Natural Gas X: Low NOx Design Series A: Initial Release Airflow Capability Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage The furnace must not be derated, orifice changes should only be made if necessary for

Gf9s series (style g) 91% downflow/horizontal 3 65 orifice, burner (natural #45) 029-21182-045 029-21182-045 029-21182-045 figure 2: downflow/horizontal natural gas furnaces (91%) fig item description gf9s100c16dh11g gf9s100c20dh11g gf9s120d20dh11g <

G43UF natural gas units are fitted with .089" sized orifices. G43UF Unit C.A.I. Orifice Size −045−1 to −6 .750" −045−7 and later .703" −070−7 and later .922" After the G43UF gas furnace has been started, the follow-

Goodman/Amana Furnace Natural Gas Burner Orifice The Amana® brand AMVC Series Gas Furnace offers energy Goodman Furnace Spark Ignitor Assembly B1401003S. $45.00 Add to American Standard, Trane Furnace Flame Sensor SEN00233. $38.00 Add. Shop our selection of Appliance Parts,

Single Stage Multi Position Furnace Service Manual refer to the current edition of the National Standard of Canada Natural Gas and Propane Installation Code (NSCNGPIC) MANIFOLD PRESSURE AND ORIFICE SIZE FOR HIGH ALTITUDE APPLICATIONS Table 1 NATURAL GAS MANIFOLD PRESSURE

SUBJECT: Residential Gas Furnace LP Conversion Kit Changes & Consolidations We are BTU and Orifice Size Guide Natural Gas Pressure L/P Gas Pressure Inches W.C. Inches W.C BTU Input 3.0" 3.5" 4.0" 11" 16,000 46 5/64 48 56 18,000

Gas Conversion Kit Natural-to-Propane for KGANP3001ALL All Condensing Furnaces, 2-Stage 80% Variable Speed, 2-Stage Non-Condensing burner orifice size. Furnace gas input rate on rating plate is for installations at altitudes up to 2000 ft.

LPM-07 NATURAL GAS TO LP GAS CONVERSION KIT INSTALLATION INSTRUCTIONS Turn off gas supply to the furnace. 2. © 2014 Goodman Manufacturing Company, L.P. is a trademark of Maytag Corporation and is used under license.

Natural Gas Tankless Water Heater is designed to supply You will need Adobe® Acrobat PDF Parts Lists Burner Orifice – LP, see the Gas Furnace LP Conversion Kit. The Goodman® GMH8 80% AFUE Two-Stage

TECHNICAL MANUAL Copyright ©2009 Goodman Manufacturing Company, These furnaces are manufactured for natural gas operation. The furnace must not be derated, orifice changes should only be made if necessary for altitude. 3.

LP Gas Orifice Kits and Sizes SV9500, SV9501 or VR8204M gas valves certified for use with Natural Gas (and so marked) to units functionally the same as the certified furnace for use with Propane Remove the Natural gas (brass) burner orifices from the

Bryant Gas Furnace Error Code 33 Your furnace then shoots natural gas close to the ignitor, igniting the gas which LH33Zs004, which will work on most Bryant, Currier, Goodman · Heil · Lennox air furnace equipped for use with natural gas

MULTI-POSITION FURNACE INSTALLER'S INFORMATION MANUAL RTI F I CE E D D E SIGN Factory Installed Orifice Sizes. FURNACE MODEL NATURAL GAS PROPANE (LP) U.S. (except NOx models) 2.15 mm 1.30 mm U.S. (California NOx models) 2.10 mm NA