2 Proper Venting of Gas Furnaces What is the Best Way to Vent a Condensing Gas Furnace? Bryant introduced the first high-efficiency condensing gas furnace in the early 1980s.

Product Description of [post_title] below:


Domestic Shipping: This item is also available for shipping to select countries outside the U.S.
International Shipping: This item is not eligible for international shipping.
Average Customer Review: 9/10

Field Replacement Furnace Vent Transition Kit, #904106 For M3RL Series Furnaces not use this kit with existing roof jacks that are not sound. B. Replace the existing furnace with the new M3RL After the M3RL furnace is set in place: 1. Choose vent pipe material based on table 1. 2.

Furnace vent pipe connections are sized for 2” (5.1 cm). pipe. Any pipe size change must be made outside the furnace casing in a verti- it may be necessary to replace the orifices. Verify natural gas input rate by clocking meter. 1.

• Some customers wrongly install a 2” vent pipe when they need to have a 3” vent pipe. Your furnace will require a 2 or 3 inch vent pipe depending on your furnace size even though all of the furnaces have a 2 inch opening where the vent pipe connects.

N/A Vent Kit Thru the Wall Assembly-Items: 2, 3, 4, 7, 8, 9, & 10 6907180 6 Manifold Door Gasket 4410136 12 Drain Valve 6900764 13 Gas Valve/Thermostat-Natural Gas 6901709 13 Gas (Contains on 36” long pipe) 6907173

The HTPV pipe used in these vents could be susceptible to corrosion, cracking and joint separation, which could result in the release of carbon monoxide into living areas, Goodman will continue to replace the entire furnace and vent with a brand new,

90+ GAS FURNACE INSTALLATION INSTRUCTIONS GAS FURNACE SAFETY Table of Contents A non-direct vent (one pipe) installation uses air from inside the Immediately call a qualified person to inspect the furnace and to replace any part of the control system and gas control

When it’s time to replace your furnace, you will be faced with many confusing questions and no clear answers. Contractors will be happy to give you options

GAS VENT INSTALLATION INSTRUCTIONS Vent pipe with 14" or larger diameter must terminate at least 2 feet higher than an adjacent wall or obstruction, if it is within 10 feet. 8. FURNACE CONNECTOR RISE B-VENT USED AS CONNECTOR

Type “L” Vent Installation Instructions General Information • AirJet “L” Vent is listed for use with modern high-effi ciency oil or gas fi red appliances with operating

Specifications Applications DuraVent’s Type B Gas Vent system. Use with natural gas or liquid propane category I and draft hood equipped appliances, and appliances tested

30 bockwaterheaters.com Engineering Manual The purpose of venting a gas or oil-fired water heater is to completely remove all products of combustion and to vent

5 Figure 2 at least 2 feet higher than an adjacent wall or obstruction, if it is within 8 feet. Vent pipe with 14” or larger diameter must terminate

Typical Installation of Furnace in Attic City of San Ramon Building & Safety Services 2401 Crow Canyon Rd., San Ramon, CA 94583 • Install vent per furnace manufacturer’s installation instructions, roof flashing and vent cap.

Fundamentals of Venting and ever, it is vital that all vent pipe slope toward the furnace. Any condensate, which may form inside the vent, will run back to the furnace. is a good practice to install vent pipe with the linear seams on top.

vent pipe installation. ‡For installations on a combustible floor, do not install the furnace floor joists, as shown in figure 12, or install the furnace on a platform, as shown in figure 13. A horizontal suspension kit (51W10) may be ordered from Lennox or use equiva-

N/A Vent Kit Thru the Wall Assembly-Items: 2, 3, 4, 7, 8, 9, & 10 6907180 6 Manifold Door Gasket 4410136 12 Drain Valve 6900764 13 Gas Valve/Thermostat-Natural Gas 6901709 13 Gas (Contains on 36” long pipe) 6907173

On venting & draining the condensing furnace. You can’t talk about venting a condensing gas furnace without also discussing draining. the vent pipe to the trap, this could be attached to a drain port in the vent elbow inside the unit or

Partially assemble Concentric Vent kit. Follow furnace installation instructions for cleaning and cementing. a. Cement “Y” ˜tting to larger diameter air inlet pipe Determine correct Concentric Vent size for the pipe diameter selected. 3.